Features |
| |
|
|
|
|
Microprocessor control |
|
|
|
|
|
|
True on line double conversion design
|
|
|
|
|
|
True sine wave output less then 3% THD
|
|
|
|
|
|
Wide input voltage range +/-25% of nominal voltage
|
|
|
|
|
|
UPS Monitoring utility software facility
|
|
|
|
|
|
SNMP management capability |
| |
|
|
|
|
Power factor correction
|
| |
|
|
|
|
Cold Start
|
| |
|
|
|
|
Versatile, modular design provides flexibility during setup and service
|
| |
|
|
|
|
Extended back-up time with battery pack |
| |
|
|
|
|
Compact size, light weight & low noise |
|
|
|
 |
|
IGBT as switching device |
|
 |
Technical Specification
Model |
000 |
0L-10K,Ø |
0L-20K,Ø |
0L-30K,Ø |
0L-40K,Ø |
0L-50K,Ø |
0L-60K,Ø |
0L-100K,Ø |
Input |
Input voltage range |
300-460V |
300-460V |
300-460V |
300-460V |
300-460V |
300-460V |
300-460V |
Frequency |
50/60Hz±5% |
Efficiency |
>86% |
Output |
VA Rating |
10KVA |
20KVA |
30KVA |
40KVA |
50KVA |
60KVA |
100KVA |
Frequency |
50Hz OR 60H (Auto Tracking) |
Output Voltage |
220V/230V/380V/400V/415V AC |
Output Voltage Tolerance |
±1% |
Frequency Stability |
±1% |
Output Wave Shape |
True Sine Wave |
Load Power Factor |
0.8 Lag |
Step load change |
±7% for 100% Load variation |
Harmonic Distortion |
Linear load <1.3%,Non linear load<3% |
Over load |
115%load for 50 seconds |
Crest Ratio |
3:1 |
Battery |
Battery Type |
Sealed Maintenance Free (SMF) / Automotive Battery (Industrial) |
Back-up Time
|
Full Load |
15/30/60/120min |
10/30/60/120 min |
10/30/60/120 min |
10/30/60/120 min |
10/30/60/120 min |
10/30/60/120 min |
Half Load |
30/60/120/240 min. |
30/60/120/240 min. |
30/60/120/240 min. |
30/60/120/240 min. |
30/60/120/240 min. |
30/60/120/240 min. |
Charging Time |
8 Hours for 90% charging
|
Charging mode |
Continuous voltage plus Trickle |
Protection |
Lightning, Transient, Spike, Sag, Surge, Blackout, Brownout, Flicker, Reverse Polarity Protection, Overload, Under and Over voltage, short circuit, Battery Over charge, Battery Low (deep discharge) and noise (EMI & RFI) as per International safety practices. |
Transfer time |
Line Fails/Recovers |
(0) Zero |
|
After Over load |
Auto Transfer to Mains |
Audible |
@1 Meter |
<50 dBA |
Indicator |
LED/LCD Display |
Input voltage, Output voltage, input frequency, Output frequency, output load etc. |
Alarm Mode |
Two State Audible |
Audible Alarms |
DC Mode, Low Battery, Over/Under Voltage, Over/Under frequency, high temperature, Over load Alarm. |
Interface |
Computer |
RS-232 |
Environment |
Temperature |
0oC-48oC |
|
Humidity |
10%-95% Non-condensing |
| True On-Line UPS with other input range, output Voltage and back-up time are also available. |
|